Grounding Size Calc NEC

Grounding Size Calc NEC
Developer: Rizvan Adzhoian
Category: Tools
Add App to Comparison

Grounding Size Calc NEC Summary

Grounding Size Calc NEC is a with in-app purchases iOS app in Tools by Rizvan Adzhoian. Released in Apr 2026 (2 months ago). Store metadata: updated Apr 26, 2026.

Store info: Last updated on App Store on Apr 26, 2026 .


0★

Ratings:

5★
4★
3★
2★
1★

Screenshots

App Description

NEC grounding size calculator for electricians, apprentices, and electrical engineers. Three calculators in one app: Equipment Grounding Conductor (EGC) from Table 250.122, Grounding Electrode Conductor (GEC) from Table 250.66 with sole-connection exceptions, and Bonding Jumper from Table 250.102(C)(1) with the 12.5% rule. Works 100% offline on the job site.

Whether you're sizing an EGC for a 200A circuit, determining the GEC for a 500 kcmil service with a ground rod electrode, or calculating a bonding jumper for parallel service conductors, this calculator gives you accurate NEC-compliant results in seconds.

THREE CALCULATORS IN ONE:

EQUIPMENT GROUNDING CONDUCTOR (EGC):
- Size EGC per NEC Table 250.122 for OCPD ratings 15A to 6000A
- Copper and aluminum conductor support
- Voltage drop adjustment per NEC 250.122(B) - proportionally increase EGC when circuit conductors are upsized
- Original and adjusted wire size selection for accurate proportional calculation
- Automatic rounding up to next standard OCPD rating

GROUNDING ELECTRODE CONDUCTOR (GEC):
- Size GEC per NEC Table 250.66 based on service conductor size
- Support for copper and aluminum service conductors
- Parallel sets calculation (1-6 sets) with automatic equivalent area computation
- Sole-connection exceptions per NEC 250.66(A), (B), and (C):
- 250.66(A): Rod, pipe, or plate electrode - GEC capped at #6 Cu / #4 Al
- 250.66(B): Concrete-encased electrode - GEC capped at #4 Cu / #4 Al
- 250.66(C): Ground ring - GEC capped at #2 Cu / #2 Al
- Five electrode types: Water Pipe, Rod/Pipe/Plate, Concrete-Encased, Ground Ring, Other

BONDING JUMPER:
- Size bonding jumpers per NEC Table 250.102(C)(1)
- Same ranges as Table 250.66 for conductors within table limits
- Automatic 12.5% rule for service conductors exceeding 1100 kcmil Cu or 1750 kcmil Al
- Parallel sets support with combined circular mil area calculation

CALCULATION RESULTS INCLUDE:
- Conductor size in AWG or kcmil with alternative material
- Exception applied with NEC section reference
- NEC article references for every result
- Detailed notes for parallel sets and electrode exceptions

NEC REFERENCES INCLUDED:
- NEC Table 250.122 - Equipment grounding conductor sizing
- NEC 250.122(B) - EGC increase for voltage drop
- NEC Table 250.66 - Grounding electrode conductor sizing
- NEC 250.66(A) - Rod, pipe, or plate electrode exception