Breaker Size Calc NEC
Breaker Size Calc NEC Summary
Breaker Size Calc NEC is a with in-app purchases iOS app in Tools by Rizvan Adzhoian. Released in Apr 2026 (3 months ago). Store last updated Jun 10, 2026
Breaker Size Calc NEC SDKs Summary
App not yet scanned for SDKs.
0★
Ratings:
Screenshots
App Description
NEC breaker size calculator for electricians, apprentices, and electrical engineers. Size overcurrent protection devices per NEC Article 240, with automatic continuous load adjustment, next-size-up rule, small conductor limits, and wire-breaker coordination. Works 100% offline on the job site.
Whether you're sizing a breaker for a 40A continuous lighting load, selecting overcurrent protection for an AC unit, or checking if a 14 AWG conductor needs a 15A breaker limit, this calculator gives you accurate NEC-compliant results in seconds. Use it as your go-to breaker sizing reference - from load analysis to conductor coordination.
BREAKER SIZE CALCULATOR FEATURES:
- All 36 standard overcurrent device ratings from 15A to 6000A per NEC 240.6(A)
- Automatic next-size-up breaker selection
- Continuous load 125% multiplier per NEC 210.20(A)
- Three load types: General, AC/Refrigeration (175%), Welder (200%)
- Small conductor protection limits per NEC 240.4(D): 14 AWG max 15A, 12 AWG max 20A, 10 AWG max 30A
- Wire-breaker coordination check per NEC 240.4
- Recommended conductor size from NEC Table 310.16 (75°C column)
- Copper and aluminum conductor support
- 6 voltage presets: 120V, 208V, 240V, 277V, 480V, 600V
- Single-phase and three-phase support
- NEC article references for every calculation result
NEC REFERENCES INCLUDED:
- NEC 240.6(A) - Standard overcurrent device ratings
- NEC 210.20(A) - Continuous load 125% rule
- NEC 240.4(B) - Next standard size up rule
- NEC 240.4(D) - Small conductor protection limits
- NEC 240.4 - Overcurrent protection of conductors
- NEC Table 310.16 - Conductor ampacity at 75°C
LOAD TYPE SUPPORT:
- General loads - 100% non-continuous, 125% continuous per NEC 210.20(A)
- AC/Refrigeration - 175% per NEC Article 440
- Welder - 200% per NEC 630.12
CALCULATION RESULTS INCLUDE:
- Recommended breaker size (standard rating per NEC 240.6(A))
- Adjusted load amps with multiplier explanation
- Recommended conductor size with ampacity from Table 310.16
- Breaker-to-wire ampacity verification
- Small conductor warnings when applicable
- Complete NEC article references for each result
PRO FEATURES (one-time purchase):
- No ads - clean interface for professionals
- Save breaker calculation history with labels
- Export calculations as PDF reports for permits and records
- Dark theme support
HOW THE BREAKER SIZE CALCULATOR WORKS:
1. Select