Wire Size Calc
Wire Size Calc Summary
Wire Size Calc is a with in-app purchases iOS app in Tools by Rizvan Adzhoian. Released in Apr 2026 (3 months ago). Store last updated Jun 11, 2026
Wire Size Calc SDKs Summary
App not yet scanned for SDKs.
0★
Ratings:
Screenshots
App Description
NEC wire size calculator for electricians, apprentices, and electrical engineers.
Determine the correct wire gauge (AWG/kcmil) for any circuit using official NEC 2023 ampacity tables and derating factors. Supports continuous and non-continuous loads, copper and aluminum conductors, 6 insulation types, and both conduit and free air installations. No internet required - works 100% offline on the job site.
FEATURES:
- Continuous and non-continuous load sizing (125% factor)
- 5 voltage presets: 120V, 208V, 240V, 277V, 480V
- Single-phase and three-phase support
- Copper and aluminum conductors: 14 AWG through 2000 kcmil
- 6 insulation types: THHN, THW, TW, XHHW-2, NM-B, USE-2
- Conduit and free air installation methods
- Temperature correction factor (NEC 310.15(B)(1))
- Conduit fill adjustment factor (NEC 310.15(C)(1))
- Termination rating check (60°C / 75°C per NEC 110.14(C))
- Overcurrent protection sizing (NEC 240.4(D))
- Optional voltage drop check when distance is provided
- PASS/FAIL indicator for quick compliance check
NEC REFERENCES:
- Table 310.16 - Ampacity in conduit/raceway
- Table 310.17 - Ampacity in free air
- Table 310.15(B)(1) - Temperature correction factors
- Table 310.15(C)(1) - Conduit fill adjustment factors
- NEC 110.14(C) - Termination temperature limits
- NEC 240.4(D) - Small conductor overcurrent protection
PRO FEATURES (one-time purchase):
- No ads
- Save calculation history
- Export calculations as PDF reports
- Dark theme support
BUILT FOR THE JOB SITE:
This app is designed by electricians, for electricians. Enter your circuit parameters, get the recommended wire size instantly - no complicated menus or unnecessary features. One-hand operation, instant results.
HOW IT WORKS:
1. Enter load current in amps
2. Select load type (continuous or non-continuous)
3. Choose voltage, phase, conductor material, insulation type
4. Set installation method and ambient temperature
5. Get recommended wire size with full derating breakdown
The calculator automatically applies:
- 125% continuous load factor
- Temperature correction for ambient conditions
- Conduit fill adjustment for conductor count
- Termination temperature limit verification
- Standard breaker size selection
PERFECT FOR:
- Licensed electricians
- Electrical apprentices
- Electrical engineers and designers
- Electrical contractors
- NEC code exam preparation
- Journeyman an